|More
Elisa
Readers|Multiskan
Readers|Strip Plate Washers|Great Deals on Washers|
Great Deals Microplate
Readers 3 Elisa Plate Readers
Pages 1 | 2 | 3 | 4 | 5 | 6
Elisa Microplate
Readers...Overstocks,
demos and remanufactured instruments. Instruments are supported with six month to three year warranty
and 6 days a week technical support. In stock items include New, demo and
remanufactured Monochromatic, 96 Well or 96/384 Well Elisa Plate Readers to include Molecular Devices VMAX, Labsystems,
Bio-tek, ThermoFisher, Dynatech, Tecan, Biorad and Bio-tek
EL 312, EL 340, EL 311
Readers (different models, please inquire).

Bio-tek PowerWave X (PRWIE/PRWSIE) UV-VIS Scanning Monochromatic Spectrophometer.
Spectral Range 200-999nm in 1 nm increments. Incubation and temperature
control.
Instrument Description
and Capabilities:
- Monochromator optical design with powerful Xenon flash lamp
- Select wavelengths from 200 to 999nm in 1 nm increments without the use of filters
- 96- and 384-well microplates
- 4-Zone™ temperature control to 50oC provides superior temperature stability
with upgraded PC software
- Ultra fast read times for 96- and 384-well formats
- With pathlengths correction, easily converts cuvette-based assays onto a microplate format
Typical Performance:
- Accuracy: < 1% at 2.0 OD, < 2% at 3.0 OD
- Linearity: +/- 1% from 0 to 3.0 OD
- Repeatability: < 0.5% at 2.0 OD, < 2% at 3.0 OD
Specifications:
- Microplates: Accomodates 96- and 384-well microplates
- Read types: Endpoint, kinetic, spectral scanning and linear scanning
- Read modes: Normal - multiple measurements are taken on each well, with enhanced performance at optical densities > 2.0 OD
- Rapid - increased speed with the best performance from 0 to 2.0 OD
- Sweep - "On the fly" measurement, for fastest possible screening
- Absorbance measurement range: 0 - 4.0 OD
- Wavelength measurement range: 200 - 999 nm.
- Minimum read speed:
- Normal - 96-well, 11 seconds; 384-well, 23 seconds
- Sweep - 96-well, 5 seconds; 384-well, 11 seconds
- Band pass: 5 nm
- Accuracy of the wavelength: +/- 2 nm.
- Repeatability of the wavelength: +/-
0.2 nm\
- Light source: Xenon flash
- Shake function: User-programmable timing and frequency
- Dimensions: 216W x 216H x 406D mm.
- Weight: 10.9 Kg.
- Ambient temperature: 18oC to 40oC
- Ambient humidity: 80% non-condensing max.
- Power consumption: 100 VA max.
Small
footprint, huge features,
Includes NIST (National
Institutes Standards & Technology)
performance documented with a calibrated and certified verification plate
for plate alignment, linearity, optical channel
matching to ensure consistent results across all reading channels and
photometric accuracy. This has it all! One year warranty on remanufactured models. New
models sell for over $18,700.
| Catalog # |
Instrument Description/Price/# in stock |
|
P97240 |
Powerwave Remanufactured
$5,995. (2) |
| P97298 |
Powerwave X Remanufactured
$5,995. (2) |
| 999888 |
Bio-Tek Gen 5 various models of PC Software
via interface connections
RS 232 serial
& parallel port |
| 9850014 |
NIST Plate |
Bio-tek PowerWave
340 96 well Monochromatic Microplate Spectrophotometer. Spectral Range
340-999nm in 1 nm increments without
the use of filters. Includes incubation and shaking.
Instrument Description
and Capabilities:
- Monochromator optical design with powerful Xenon flash lamp
- Select wavelengths from 340 to 999nm in 1 nm increments without the use of filters
- 96-well microplates
- 4-Zone™ temperature control to 50oC provides superior temperature stability
with upgraded PC software
- Ultra fast read times for 96-well formats
- With pathlengths correction, easily converts cuvette-based assays onto a microplate format
Typical Performance:
- Accuracy: < 1% at 2.0 OD, < 2% at 3.0 OD
- Linearity: +/- 1% from 0 to 3.0 OD
- Repeatability: < 0.5% at 2.0 OD, < 2% at 3.0 OD
Specifications:
- Microplates: Accomodates 96-well microplates
- Read types: Endpoint, kinetic, spectral scanning and linear scanning
- Read modes: Normal - multiple measurements are taken on each well, with enhanced performance at optical densities > 2.0 OD
- Rapid - increased speed with the best performance from 0 to 2.0 OD
- Sweep - "On the fly" measurement, for fastest possible screening
- Absorbance measurement range: 0 - 4.0 OD
- Wavelength measurement range: 340 - 999 nm.
- Minimum read speed:
- Normal - 96-well, 11 seconds;
- Sweep - 96-well, 5 seconds;
- Band pass: 5 nm
- Accuracy of the wavelength: +/- 2 nm.
- Repeatability of the wavelength: +/-
0.2 nm\
- Light source: Xenon flash
- Shake function: User-programmable timing and frequency
- Dimensions: 216W x 216H x 406D mm.
- Weight: 10.9 Kg.
- Ambient temperature: 18oC to 40oC
- Ambient humidity: 80% non-condensing max.
- Power consumption: 100 VA max.
Includes
incubation and shaking. Small footprint, huge features. Includes NIST (National
Institutes Standards & Technology)
performance documented with a calibrated and certified verification plate
for plate alignment, linearity, consistent results across all reading channels and
photometric accuracy. One year warranty on remanufactured models. New
models sell for over $18,700.
| Catalog # |
Instrument Description/Price/# in stock |
| P97231 |
Powerwave 340 Remanufactured
$5,995. (2) |
| 999888 |
Bio-Tek Gen 5 various models of PC Software
via interface connections
RS 232 serial
& parallel port |
| 9850014 |
NIST Plate |
Tecan
Sunrise Microplate Readers. Spectral Wavelength Range 340-750nm, with four
standard
filters 405, 450, 492, 620nm. 340 to 399nm: 0 to 3.0 OD, 400 to 750nm: 0
to 4.0 OD. Designed to read a
96-well plate in 6 seconds in dual wavelength mode (8 seconds) with accuracy and
linearity better than 1% and precision
within 0.5%. 12 measurement
channels and 1 reference channel. Linear shaking in 4 different
modes.
Endpoint, kinetic assays read time 5 seconds. Small footprint,
easy to use, huge features. Includes NIST (National
Institutes Standards & Technology) performance documented
with a calibrated and certified verification plate for plate alignment,
linearity, filter installation, optical channel matching to ensure
consistent results across all reading channels and photometric accuracy.
Three year warranty on all new and remanufactured models.
| Catalog # |
Instrument Description/Price/# in stock |
| P97269 |
Tecan Sunrise *NEW (1) |
| P97259 |
Tecan Sunrise Remanufactured (3)
$3,295. |
| 9850015 |
NIST Plate |
Bio-tek Microplate Readers.
Spectral Range 340-750nm OR 400-750nm in 5nm increments.
Incubation, temperature control and shaking.
5 second
read and 405nm filter included. Endpoint, single and dual
wavelength reads. Absorbance range 0.000 to 4.000 OD with narrow bandwidth
filter included or purchase additional at later date. Models come with Includes NIST (National
Institutes Standards & Technology)
performance documented with a calibrated and certified verification plate
for plate alignment, linearity, optical channel
matching to ensure consistent results across all reading channels and
photometric accuracy. Turnkey systems to interface with printer for full operation. One year warranty on all remanufactured models. Will export data
using printer and cable
#99866.
| Catalog # |
Instrument Description/Price/# in stock |
|
P97285 |
340-750nm Remanufactured $2,495.
(3) |
P97267 |
400-750nm Remanufactured $1,995. (17) |
| 99866 |
Interface printer and cable $389. |
| 9850014 |
NIST Plate |
iEMS
96 well Microplate Reader. Spectral Range 340-850nm to include upper and lower temperature controlled clamshell
plates provide built-in temperature control and prevent plate condensation.
With shaking capabilities and wide measurement range of up to 4.000 OD makes
it an ideal instrument for Microbiological studies top provide growth curves
output. Operation range via PC Spectrosoft. Wavelength range 340-850nm and
comes with 340nm filter and user's choice of 2 filters in an eight place
filter wheel. Includes NIST (National
Institutes Standards & Technology)
performance documented with a calibrated and certified verification plate
for plate alignment, linearity, filter installation, optical channel
matching to ensure consistent results across all reading channels and
photometric accuracy. Three year warranty on all models.
Turnkey
system.
100-240 V. Can easily reset to 220 Voltage.
| Specifications: |
| type of
filters |
8 position
filter wheel with installed filters: 340, 405, 414, 450, 492, 540, 620, 690nm
(2 of choice) |
| wavelength
accuracy |
2nm stand
alone, 1nm with PC software |
| wavelength
range |
340-850nm |
| linearity |
0...4.000 A
max. dev. less than 2%
0...3.000 A
at 340 nm and 620 nm |
| dynamic range |
0.000 A ...
6.000 A |
| resolution |
0.001 A |
| accuracy |
1% or 0.002
A, whichever is greater (0...2.000 A), 2% (2.000...3.000 A) |
| precision |
CV<0.2% or
0.002A, whichever is greater (0...3.000A)
CV<1.0% at 4.000A |
| Measurement
speed |
6 seconds on
96 well plate |
|