Contact Us: 1.941.840.2591 info@finstruments.com


|More Elisa Readers|Multiskan Readers|Strip Plate Washers|Great Deals on Washers|

Great Deals Microplate Readers 4 Elisa Plate Readers
Pages 1 | 2 | 3 | 4 | 5 | 6

Elisa Plate Readers...Overstocks, demos and remanufactured instruments. Instruments are supported with six month to three year warranty and 6 day a week technical support.  In stock items include New, demo and remanufactured Monochromatic, 96 Well or 96/384 Well Elisa Plate Readers. MTX Lab Systems stocks Molecular Devices, Labsystems, ThermoFisher, Dynatech, Tecan, Biorad and Bio-tek Readers with full one to three year warranty.

Biotek Quant Monochromatic Microplate Spectrophometer. UV-VIS Scanning Monochromatic Spectrophometer. Spectral Range 200-999nm in 1 nm increments.

Instrument Description and Capabilities:    

  • Ultra fast read times for 96- and 384-well formats
  • With pathlengths correction, easily converts cuvette-based assays onto a microplate format

Typical Performance:

  • Accuracy: < 1% at 2.0 OD, < 2% at 3.0 OD
  • Linearity: +/- 1% from 0 to 3.0 OD
  • Repeatability: < 0.5% at 2.0 OD, < 2% at 3.0 OD

Specifications:

  • Read types: Endpoint, kinetic, spectral scanning and linear scanning
  • Read modes: Normal - multiple measurements are taken on each well, with enhanced performance at optical densities > 2.0 OD
    • Rapid - increased speed with the best performance from 0 to 2.0 OD
    • Sweep - "On the fly" measurement, for fastest possible screening
  • Absorbance measurement range: 0 - 4.0 OD
  • Wavelength measurement range: 200 - 999 nm.
  • Minimum read speed:
    • Normal - 96-well, 11 seconds; 384-well, 23 seconds
    • Sweep - 96-well, 5 seconds; 384-well, 11 seconds
  • Band pass: 5 nm.
  • Accuracy of the wavelength: +/- 2 nm.
  • Repeatability of the wavelength: +/- 0.2 nm.
  • Light source: Xenon flash
  • Shake function: User-programmable timing and frequency

Endpoint, single and dual spectral range reads, kinetic reads, Spectral scanning to find peak absorbance in any microwell, spectral skans and well area scanning.  Absorbance measurement range 0-4.000 OD, ±2 nm accuracy, ±0.5nm at 2.OD repeatability, 2.4nm bandpass. Extensive onboard data analysis and storage for DNA quantitation and 260/280 ratio, curve fitting options, more features explode with PC software.  Small footprint, huge features.  MTX Lab Systems, Inc. includes NIST (National Institutes Standards & Technology) performance documented with a calibrated and certified verification plate for plate alignment, linearity, filter installation, optical channel matching to ensure consistent results across all reading channels and photometric accuracy. One year warranty on remanufactured models. 

Catalog # Instrument Description/Price/# in stock
P97239 µQuant Remanufactured  (4) $5,995.
999888 Biotek Gen 5 PC Software NEW fully licensed
9850014 NIST Plate

Dynex MRX II & MRX Model 96 Well Plate Reader. Spectral Range 400 to 850nm. Installed 3 standard onboard filters 405, 450, 492nm or user's choice of filters. Single/dual or multiple wavelength readings; dual wavelength <6 seconds, single wavelength reads <4 seconds. Endpoint, kinetic plate reads to 1000 per plate, plate shaking, calculation range. Dynamic range -0.100 to 4.000 OD. Built-in onboard PC software for full data analysis, storage of assay protocols, assay results and expanded operations. Includes NIST (National Institutes Standards & Technology) performance documented calibrated and certified verification plate for plate alignment, linearity, filter installation, optical channel matching to ensure consistent results across all reading channels and photometric accuracy.  Includes line cord, fully remanufactured, 6 days a week technical support and one year warranty. User needs optional monitor, printer, mouse and keyboard to complete system.

Catalog # Instrument Description/Price/# in stock

P97276

MRX II Remanufactured (3) $2,995.
P97275 MRX Reader Remanufactured  (3) $2,995.
6723121  DMP Printer, Monitor, Keyboard, Mouse

Dynex MRX Revelation and Revelation TC 96 Well Microplate Reader. 400 to 850nm Spectral Range and temperature control.  3 standard onboard filters 405, 450, 492nm or user's choice of filters. Single/dual or multiple wavelength readings; dual wavelength <6 seconds, single wavelength reads <4 seconds. Accuracy:  2.5% or 0.005 OD whichever is greater (0 to 3.5 OD)  Linearity:  0.000 to 2.000 OD +/- 1% and 2.001 to 3.500 OD +/- 1.5% Dynamic Range:  -0.100 to 4.000 OD Endpoint, kinetic plate reads to 1000 per plate, plate shaking, calculation range.  Built-in PC software for full data analysis and expanded operations. *Revelation TC model has temperature control.
Stability - Plus/Minus 0.5C, Accuracy - Plus/Minus 1C, Time to temperature - 8 minutes, Temperature range - Ambient to 63C.  User friendly: Create Quick Start buttons for one-touch assay analysis and GLP compliant. On-board self-diagnostics.
Includes NIST (National Institutes Standards & Technology) performance documented with a calibrated and certified verification plate for plate alignment, linearity, filter installation, optical channel matching to ensure consistent results across all reading channels and photometric accuracy. Includes line cord, fully remanufactured, one year warranty. User needs optional monitor, printer, mouse and keyboard to complete system.

Catalog # Instrument Description/Price/# in stock

P97287

MRX Revelation Remanufactured

P97277

MRX Revelation Temperature Control  Remanufactured (3)
6723121  DMP Printer, Monitor, Keyboard, Mouse

Next Page -->

Washers, Incubator and Accessory page!

|More Elisa Readers|Multiskan Readers|Strip Plate Washers|Great Deals on Washers|

 
Copyright © 2014. All Rights Reserved HOME | FLUORESCENCE | WASHERS | READERS | PIPETTORS | DISPENSERS | CONTACT