|Biotek Synergy HT
|Molecular
Devices Gemini EM|
Bio-tek Synergy™
HT Multi-Detection Microplate Reader
Fluorescence, TRF, Absorbance and Luminescence
Microplate Reader Equipped with UV-VIS Fluorescence and Luminescence
for top- and
bottom- read assays with one year warranty

|
Instrument Description
and Capabilities:
Todays research requires that instrumentation be cost effective- reliable and easy to use. In response to those requirements- BioTek Instruments has developed the Synergy HT Multi-Detection Microplate Reader. This plate reader for fluorescence- absorbance and luminescence measurements was designed with an emphasis on superior performance in all detection methods. Unlike many multi mode microplate readers- the Bio-Tek Synergy HT utilizes a unique dual-optics design.
When making fluorescence determinations- the Bio-Tek Synergy HT uses a tungsten halogen lamp with interference filters for wavelength specificity in conjunction with a PMT detector. The tungsten halogen lamp produces a large amount of light at a constant intensity- providing increased sensitivity and repeatability. Specially designed fluorescent interference filters prevent light leakage from excitation wavelength to the emission wavelength- particularly important with fluorescent compounds with small Stokes shifts. In addition- the ability to use filters with different bandpasses allows the investigator to tailor their fluorescence measurements to their experiment more effectively.
The low noise PMT is operated in digital photon integration mode for high performance luminescence measurements.
When absorbance measurements are made- the instrument switches to a Xenon Flash Lamp and a monochromator for wavelength selection. The use of a xenon flash lamp allows for both UV and visible light absorbance measurements. The monochromator provides wavelength selection from 200 to 999 nm in 1 nm increments. Thus- dual-optics design allows the investigator to have three different reading modes without compromise.
The Bio-Tek Synergy HT has a 4-Zone temperature control system that ensures superior temperature uniformity necessary for kinetic assays. With a compact footprint and robot-accessible carrier design- the Bio-Tek Synergy HT
is also compatible with most automated systems.
| Specifications: |
|
|
Detection methods: Fluorescence, Time Resolved
Fluorescence, Luminescence, UV-Visible Absorbance
|
|
|
Microplate Types: 6- to 384-well plates; PCR plates
|
|
|
Temperature Control: 4°C above ambient to 50°C
|
|
|
Capable of mixing via shaking option
|
|
|
Automation Compatible
|
|
|
Absorbance Wavelength Range: 200 – 999 nm, 1nm
increment
|
|
|
Fluorescence Wavelength Range: 200 – 700 nm (900 nm
option)
|
|
|
Luminescence Wavelength Range: 300 – 700 nm
|
|
|
|
|
Includes the Following:
- Synergy HT Reader
- Communication Cables
- PC Workstation
- Operating Software
- Fully Serviced & Tested
- 90-Day Parts & Labor Warranty in the US
|
|
|
Specifications: |
|
Detection method |
Fluorescence, Time Resolved Fluorescence,
UV-Visible Absorbance Luminescence |
|
Detection method |
End-point, kinetic, spectral scanning, well-area scanning |
|
Microplate types |
6- to 1536-well plates (luminescence 1-384)
PCR plates
Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
|
Temperature control |
4°C above ambient to 65°C |
|
Shaking |
Included |
|
PC
Software |
Gen5™
to be purchased
Control through USB or serial port |
|
Reagent Delivery |
10-300 microletres in 1 in microletre increments |
|
CV Precision |
less than 0.7 percent at 300 ul |
|
Sample Delivery |
Pipetted Probe Increments 0.1 microlitre increments from 1-100 microletres |
|
System Throughput (Clinical Chemistry) |
190 test/hr- 280 using (ISE) test/hr |
|
Coagulation Mode |
70 PTs /hr |
|
Photometric Resolution |
0.001 O.D. |
|
Dimensions |
17"W x 17.5"D x 14.5"H (43.5 x 44.5 x 37.3 cm) |
|
Weight |
60 lbs (27 kg) |
|
Catalog # |
P97238 |
|
|
Warranty
information:
Instruments come complete with NIST certification and documentation, line cord and six days a week technical
support. Remanufactured model
with one year warranty. High quality instrument made in USA. Easily reset to 220 Volt.