Biotek FL600 96/384 Reader
Fluorescence and Absorbance Microplate Reader SOLD

Instrument Description:

The FL 600 is a Absorbance and Fluorescence instrument for measuring samples in various microplates. This Reader fulfills requirements for numerous fluorescence and absorbance applications in research and routine investigations.

The Fluorescence filters are arranged in filter wheels; four excitation filters and four emission filters respectively as noted below in a 6 place filter wheel. Handles 6, 48, 96, and 384 well plates. With the wavelength range of 360-750nm fluorescence spectral range.
The absorbance wavelength range of 340-750nm with your choice of filters covers the full spectral range. KC 4 PC software includes various methods of data capture, including kinetic readings and end point. Standard reads and data can be downloaded into Excel for further curve fits and specified data to meet assay requirements. Sensitivities can be two and to three times more sensitive than specified by use of KC 4 PC software. Different detection techniques with one instrument change of measurement directions (top / bottom) by PC software.  Thermal incubation at 
+5º C to + 42º C, with 3 settings for shake-High 25Hz, Medium-17Hz and Low 12.5Hz. 

Dual optical channels allow measurements from above or below the plate by mouse-click. Light to and from the samples is focused by a lens and high quality excitation and emission filters are easily accessible and can be reconfigured to meet dozens of application requirements.  Each filter wheel holds up to six filters with eight filters installed for fluorescence readings to total twelve filter positions.  Six filters for absorbance can be accommodated.  Suggested use with black clear bottomed plates for bottom-to-top readings. Optimal use with black plates to prevent cross-contamination.
Easily reset to 220 Volt.

 
Lamp life

Minimum 2000 hours

Fluorescence Wavelength Range 360 - 750 nm
Excitation Standard Filters range and installed filters 300-650nm available 6 position wheel 485nm, 530nm, 590nm, 360nm
Choice of 3 or custom
Emission Standard Filters range and installed filters 350-750nm available 6 position wheel 450nm, 530nm, 590nm, 545nm
Choice of 3 or custom
Absorbance filter wavelength range
340-750nm 6 position wheel

Your choice bandwidth filters
No Absorbance Filters included

Temperature range

Ambient +6º C to + 50º C

Vertical Shake

Low, mid and high shake

Micro well plate type

6, 48, 96 and 384 well plates
for top or bottom readings

Interface system

Serial RS-232C port 

Bio-tek FL 600 Ordering information

Catalog #P97073 Remanufactured

KC 4 PC Software on CD ROM $2,200. NEW

Catalog #5290512

Accessories and warranty information:

Comes with line cord, manual, and six days a week technical support.
KC 4 PC Software additional. Remanufactured model with one year warranty.