Luminescence Models
|Luminoskan Model|Luminoskan Ascent|Dynex MLX Model |
|Dynex MLX Model w/3 dispensers|
 |Perkin Elmer Victor 2|Perkin Elmer Victor 2 with dispensers|
|Tecan Spectrofluor Plus|Tecan Genios|


Luminoskan Model 96 Well Readers

Luminoskan is the top of the range research instrument for applications that demand flexibility.  It is suited for applications with or without temperature control such as ATP studies. These models do not come with include temperature control.

Specifications:

Product Features

  • 6 Decade Measurement Range
  • Choice of 8 Measurement Modes
  • PC Spectrosoft Software specifically designed for Luminoskan

Product Specifications

  • Sensitivity: < 0.5 fmol ATP 9.9 x 10-21 moles Alkaline Phosphatase in 50µl LumiPhos® 530 at 37ºC
  • Detector: Photomultiplier tube (PMT) with Bi-alkali Photocathode. Hamamatsu R1527.
  • Spectral response (PMT): 185-680 nm. Peak 400 nm.
  • Half Band Width (HBW): 210-560 nm.
  • Dynamic Range: 6 Decades
  • Measurement Range: 0.01-10,000 RLU
  • Measurement Units: Relative Light Units (RLU)

On Board Data Reduction

  • Multiplication Factor: 0.01 - 1000

  • Threshold (LIMIT): +/-
  • Threshold (DLIMIT): +/0/-
  • Results Units: RLU, µmol/l, mmol/l, g/dl, g/l, mg/l, mg/dl, U/l, U/ml, U/µl, IU/l, IU/ml, IU/µl
  • Blank Modes: Well, Random, Row, Column.
  • Dimensions (mm): 660(w) x 495(d) x 280(h)

Measurement Modes

  • Single: 100 ms reading per well fast scan mode.
  • Integral: SIGNAL ( i )
    Integrates the reading over TOTTIME.
    Max. TOTTIME: 999.9 seconds.
    LAGTIME: 0 - 999.9 seconds.
  • Integral 1: SIGNAL ( i 1 ) As Integral but reads during the dispensing operation.
  • Peak: SIGNAL ( p )
    Reports the Maximum signal measured during the TOTTIME.
    Max. TOTTIME: 999.9 seconds.
    LAGTIME: 0 - 999.9 seconds.
  • Slope: SIGNAL ( sl )
    Rate of change in signal during TOTTIME. RLU/s.
    Max. TOTTIME: 999.9 seconds.
    LAGTIME: 0 - 999.9 seconds.
  • Continuous: SIGNAL ( c )
    Takes 50 equidistant readings during the TOTTIME. Graphical printout.
    TOTTIME range: 1 - 999.9 seconds.
    LAGTIME: 0 - 999.9 seconds.
  • Continuous 1: SIGNAL (cl )
    As Continuous but readings are taken during the dispense operation.
  • Repeat Scan: SIGNAL ( rs )
    Kinetic Mode. Define the number of readings (NPOINTS), the interval time (INTTIME) and the integral time (PMETIME).
    NPOINTS: 5 - 50
    INTTIME: 1 - 9999 seconds
    PMETIME: 0.1 - 999.9 seconds
    LAGTIME: 0 - 9999 seconds

External Software

Catalog #

P30105

Luminoskan RT 96 Well Reader
4 injectors included

Catalog #

6723108

Spectrosoft PC Software