Features: |
Visible
Spectrum
Model 341/346
(Click on photo for synopsis) |
Visible Spectrum
Model 314
(Click on photo for
synopsis) |
Ultraviolet Infrared
Visible
Spectrum
Model 347
(Click on photo for synopsis) |
Ultraviolet Infrared
Visible
Spectrum
Model 349
(agglutination &
turbidity readings)
(Click on photo for synopsis) |
Visible
Spectrum
Model 355 EX
96 well
(click on photo
for synopsis) |

Stop Running Around! |
 |
 |
 |
 |
 |
|
Spectral range |
340-750nm
400-750nm |
400-750nm |
340-750nm |
340-750nm |
400-750nm |
|
Max linearity deviation |
±2.0% at
0.2000A |
±1.5% at 0-2.000A |
±1.0% at 0-2.000A |
±1.0% at 0-2.000A |
±2% or 0.0007 A,
typical value ±1.5% |
|
Dynamic range |
0-2.000A |
0-2.000A |
0-3.000A |
0-3.000A |
0-3.5 Abs |
|
Accuracy |
±1.5% |
±1%
(at 492nm, 1.1A) |
± 1%
(0-2.5 OD at
540nm) |
± 1%
(0-2.5 OD at
540nm ) |
±2% or 0.007 A,
typical value +1% (0-2.0 A) |
|
Precision |
CV<-0.5% |
CV<0.2%
<0.2%
at 405nm |
CV<0.5%
<0-2.5 OD
at 405nm |
CV<0.%
<0.2.5%
(at 405nm) |
CV<0.5% or 0.007 A,
|
|
Filter arrangement |
8 position filter wheel
w/2 filters of choice
(b) |
2 filters in holders of
choice
(a) |
8 position filter wheel
w/2 filters of choice
(b) |
8 position filter wheel
w/2 filters of choice
(b) |
(Choose TWO),
340, 405, 414, 450, 492,540, 550, 570, 595, 620, 650,
or exchange or purchase as necessary
Additional and special wavelengths available |
|
(a) (Choose ONE) of
any wavelength, or exchange or purchase as necessary
(b) (Choose TWO), 340, 405, 414, 450, 492, 540, 550, 570, 595, 620,
650, 690nm
or exchange or purchase as necessary
Additional and special wavelengths available
Or,
405, 450nm included as standard |
|
Reading speed |
45 seconds |
5 seconds |
5 seconds |
5 seconds |
5 seconds |
|
Onboard Measurement
modes |
single/dual wavelength, two point,
kinetic |
single wavelength,
w/Spectrosoft-two point, kinetic, multiwavelength; Linear Regression &
Point-to-Point |
single/dual wavelength,
two point, kinetic,
multiwavelength;
Linear Regression
& Point-to-Point |
single/dual wavelength,
two point, kinetic, multiwavelength,
agglutination;
Linear Regression
&
Point-to-point |
Single/dual wavelength,
endpoint, single wavelength kinetic, two point, cut-off
calculations, curve fit algorithms.
Memory holds 64 assay protocols |
|
Cutoff calculations |
no |
fixed |
fixed |
fixed, floating |
fixed |
|
Curve fits |
PC or Excel
Software
controlled |
PC or Excel
Software
controlled |
PC or Excel
Software
controlled |
PC or Excel
Software
controlled |
PC or Excel
Software
controlled |
|
Shaking |
not included |
not included |
Stacker model only |
yes |
3 speed linear shaking |
|
Scanning over well |
not included |
not included |
not included |
yes, 20 readings/well |
yes |
|
Onboard printer |
yes onboard |
no, need
software |
yes onboard |
yes onboard |
yes onboard |
|
Interface connections |
serial printer |
serial &
parallel printer |
serial &
parallel printer |
serial &
parallel printer |
serial &
parallel printer |
|
Warranty |
2 year warranty |
2 year warranty |
3 year warranty |
3 year warranty |
1 year warranty |
|
PC Software |
**Spectrosoft |
**Spectrosoft |
**Spectrosoft
or Deltasoft
|
**Spectrosoft |
**Spectrosoft |
|
NIST Plate |
**Two
models |
**Two
models |
**Two
models |
**Two
models |
**Two models |
|
Accessories |
Lamp # 9864607 - $49.75
Thermal Paper# 9850053 |
Lamp # 9864607-
$49.75 |
Lamp # 9864607 - $49.75
Thermal Paper# 9850053 |
Lamp # 9864607 - $49.75
Thermal Paper #9850053 |
Lamp # 9864607 - $49.75
Thermal Paper #9850053 |
|
Plate type |
96 Well and
breakable plates |
96 Well and
breakable plates |
96 Well and
breakable plates |
96 Well and
breakable plates |
96 Well and
breakable plates |
|
Ordering Information |
#P97155 341model $2,195.
Remanu.
#P97156 346 (UV) model
Remanu. $2,495. |
#P97161 314
Model
See great deals
Remanu. |
#P97170
$3,495. Remanu.
#P97180
$4,995.
New |
#P97190 New |
#P21187 EX New $4,995.
#P97192 EX Remanu.
$3,290. |