Microplate Instrumentation Specialists

          Ordering Information
          Phone   1.800.848.6474   
          Phone 01.703.821.1045
          Fax      01.703.821.1046
          Email  
info@mtxlsi.com

Additional  in-stock Fluorescence Plate Readers:

|Cytofluor 4000|BMG Fluostar |BMG Fluorstar Galaxy|

|Tecan Spectrafluor|Thermo Electron Ascent CF|

|Tecan Spectrafluor Plus |

|Perkin Elmer Victor 2 with injectors|

|Perkin Elmer Victor 2| Perkin Elmer Victor|

|Thermo Electron/Labsystems Ascent with injector|

|Thermo Electron/Labsystems Finstruments Fluorescence|


|Fluoroskan I|Accessories|


TECAN SpectraFluor Fluorescence and
Absorbance Readers $9,995.


Description:

The SPECTRAFLUOR is a fully automatic, computer controlled Absorbance and Fluorescence instrument for measuring samples in a microplate. The instrument fulfills the requirements for numerous fluorescence and absorbance applications in research and routine investigations.

The filters are arranged in filter slides; four excitation filters and four emission filters respectively as noted below. Handles 6, 24, 96, 384 and 1536 well plates. Spectral range 360-700nm for fluorescence.
230-750nm absorbance spectral range. Sensitivity 3 pg fluorescein/ well or <8 fmol well The emission signal is measured by a highly sensitive PMT. Different detection techniques with one instrument change of measurement directions (top to bottom, bottom to top) by PC software.  Thermal incubation at 
+5º C to + 40º C.

Dual optical channels allow measurements from above or below the plate by mouse-click. Light to and from the samples is focused by a lens and high quality excitation and emission filters are easily accessible from the front of the instrument. Each filter slide holds up to four filters with eight filters onboard for fluorescence. Orbital shaking and temperature control are standard.

Specifications:

Light source

High energy Xenon flash lamp

Detector

Side window, low dark current photomultiplier tube

Plate Shaking 3 intensities

Linear and Orbital shaking in three different speeds

Fluorescence Spectral Filter Wavelength Range 340 - 700 nm
Fluorescence Sensitivity Sensitivity 1.5 picogram fluorescein on each well or <4 fmol well
Excitation Filters
(Choice of 2 filter pairs for Fluorescence readings)
Advise user's choice of filters
Emission Filters
(Choice of 2 filter pairs for Fluorescence readings)
Advise user's choice of filters
Absorbance Spectral Filter Wavelength Range

230-750nm

Absorbance Filters
(Choice of 2 filter for absorbance)

Advise user's choice of filters

Temperature range

+5º C to + 40º C

Microwell Plate Type

6, 24, 96, 384 well plates

Interface system

Serial RS-232C port 

Ordering information

Catalog #P97083 Remanufactured
(3 in stock)

Additional information:

Instruments come complete with line cord, PC software and six days a week technical support. Remanufactured model with one year warranty. Several in stock.

Microplate Instrumentation Sales, Service and Support since 1982.

               Fluorescence Filters and Applications              click here!